Features:
■3.5 inch LCD display: analog ECG, text display,
■The simulated human has obvious anatomical features, real handfeeling, uniform skin color, realistic shape and beautiful appearance.
■Simulated vital signs:
· In the initial state, the pupil of the simulated human LCD dilates and the carotid artery has no pulsation.
· During compression, simulate thepassive pulsation of human carotid artery, and the pulsation frequency is consistent with the compression frequency.
· After successful rescue,the simulated human LCD pupil returned to normal and the carotid artery started to beat autonomously.
· LCD pupil zoom and carotid pulsation can be turned on and off by the switch.
■ Artificial respiration and externaI cardiac compression are available. The standard airway can be opened, and the airway indicator light turns on.
■ Three operation modes: CPR training, mode assessment and practical assessment.
· Mode 1: CPR training, including pressing and blowing training.
· Mode 2: mode assessment: within theset time,according to the 2020 International Cardiopulmonary Resuscitation Standard,correctly press and blow the air at a ratio of 30:2 to complete 5 cycles.
· Mode 3: Practical assessment. The teacher can set the operating time range, operating standards, cycle times, operating frequency,and the ratio of pressing and blowing.
Functions of Controller Display Screen:
■ Electronic monitoring: the electronicindicator light displays the open and pressed parts of the monitoring airway. The correct and wrong counts of artificial respira-tion and chest compressions.
Real time pressing frequency and average pressing frequency are displayed when pressing.
■Voice prompt: Chinese voice prompt throughout the training andassessment can be turned on and off, and the volume can be adjusted.
Voice prompts that the pressing speed is too fast or too slow
■Barcode display air blowing volume:the correct air blowing volume is 500 600ml-1000ml:
· When the air blowing volume is too small, the bar code is yellow.
· When the air blowing volume is appropriate,the barcode is green.
· When the air blowing volume is too large, the barcode is red.
· The tidal volume blown in is too fast or too large, resulting in the indicationof gas entering the stomach; Digital counting display; Error language prompt;
■ The bar code displays the pressing depth, and the correct pressing depth is 5-6cm:
· When the pressing depth is too small, the barcode is yellow.
· When the pressing depth is appropriate,the barcode is green.
· When the pressing depth is too large, the barcode is red.
■ The correct rate of operation can be set automatically.
■You can set the operation time by yourself,in seconds.
■Operating frequency:100-120 times/minute accordingto 2020 standard, and the value can also be set by yourself.
■Power supply status:220V power supply is adopted, and 12V power supply isoutput after voltage stabilization by voltage regulator.(Lithium battery can be added for direct use without external power supply)
Printer Function:
■Print the operation process after the operation.
■The transcript covers the operation mode, consciousness judgment, first aid breathing, pulse check, breath check, foreign matter removal, operation frequency, the ratio of pressing and blowing,the number of cycles,the number of pressing andblowing in each cycle,the number of correct/wrong pressing, the cause and number of pressing errors, the cause and number of correct/wrong blowing, the cause of wrong blowing, the setting time,the operation time,and the assessment.
Material Characteristics:
■The face skin, neck skin, chest skin and hair are made of imported thermoplastic elastomer mixed glue material, which ismade of stainless steel mold and iniected by injection molding machine at high temperature. It has the characteristics of accurate anatomical marks, real feel, uniformskin color,lifelike shape,beautiful appear-ance, durability, no deformation after disinfection and cleaning, and convenientdisassembly and replacement. Its materials have reached the same level abroad.
★ Basic Care:
■ Arm venipuncture,injections,fluid(blood) transfusion, subcutaneous deltoidinjections, enema method, female catheterisation, male catheterisation, female blad-der irrigation, male bladder irrigation, fistula drainage,gluteal intramuscular injections.
Standard Set Configuration:
■One advanced full body resuscitation manikin;
■One advanced display controller;
■One luxury extra thick oxford bag;
■One resuscitation pad;
■One power adapter;
■One data line;
■One box of barrier facial mask(50 sheets / box);
■Four sets of interchangeable lung sac devices;
■One replaceable facial skin;
■Two rolls of thermal printing paper;
■One set of interchangeable injection modules;
■One patient gown;
■One nasogastric tube;
■One urinary catheter;
Alternative Accessories:
■Computer (user configured or optional)
■Lithium batteries(No external power supply required)
Printer Function:
■RF remote controller,the teacher can set the operation process through the remote controller. Control CPR start, stop, mute, pupil change,pulse,printer and other functions.You can also make conscious judgment, call for first aid, check your pulse, check your breath, and remove foreign matters for recording.